Programming Properties

The Properties presented in the Programming tab of the Properties window will depend on the current selection in the active Design View window (Page, Popup Page, Sub-Page or Button). Some properties also only apply to specific panel types.

Programming Properties
Feedback Feedback - Select the type of feedback to associate with this button (channel, inverted channel, always on, momentary, or none).
Address Port Select or enter the port to which the selected element's Address Code will be associated. The options are "1" (the default setting) and "0-setup port":
Programming Properties (Cont.)
Address Code Select or enter the address code sent to the master on the specified Address Port. The options available to the Address Code property depend on the Address Port selection:
Programming Properties (Cont.)
Address Code Click on None to leave the Address Code unspecified.
Channel Port Select or enter the port to which the selected button's Channel Code will be applied. The options are "1" (the default setting) and "0-setup port":
Channel Code Select or enter the channel code sent to the master on the selected port. The options available to the Channel Code property depend on the Channel Port selection:
Programming Properties (Cont.)
Level Control Type These options allow General and Multi-State General Buttons to directly control a level without the need for NetLinx code.
Level Port Select or enter the port to which the selected element's Level Code will be associated. The options are "1" (the default setting) and "0-setup port":
Level Code Select or enter the level code sent to the Master on the selected port (none, 1, or auto-assign).
Programming Properties (Cont.)
Level Function Select the desired level function for the selected Bargraph or Multi-State Bargraph button.
Level Control Value
  • For Absolute level control, this value determines the level value that will be recalled by this button.
  • For Relative level control, this value determines the amount of adjustment relative to the current level resulting from this button. For relative level control, this value can be entered as a positive integer (to raise the relative level setting) or a negative integer (to lower the relative level setting).

    | | Level Control Repeat Time | This value determines the repeat time (in 1/10th-second increments) for relative level control. | | Range Low | Enter the bottom of the level range (0-255). | | Range High | Enter the top of the level range (0-255). | | Range Inverted | If set to Yes, the range is inverted, so that the top of the level range is 0 and the bottom of the range is 255 on both the X and Y axis (default = No). | | Range Time Up | Specify the amount of time (in 1/10th seconds) it will take for the Bargraph to go from the bottom to the top of the specified range (default = 2). | | Range Time Down | Specify the amount of time (in 1/10th seconds) it will take for the Bargraph to go from the top to the bottom of the specified range (default = 2). |