Network Addresses
Use the options in the Networking Addresses dialog to change the network settings for a specified NetLinx master (FIG. 288).
FIG. 288 Networking Addresses dialog
- NXI masters are always set to Device = 0.
If the target Master has security applied, NetLinx Studio will prompt you for a User Name and Password in order to change these settings. See the
NetLinx Master Security section on page 133
for details.
Changing the System Number on a NetLinx Master
- Select Diagnostics > Network Addresses to access the Network Addresses dialog.
- At the top of the dialog, specify a new System number in the System field.
- Click the Reboot Master button to reboot the master and accept the new changes. Allow 20-30 seconds for the master to reboot.
Setting the IP Address for a NetLinx Master
- Select Diagnostics > Network Addresses to access the Network Addresses dialog (see FIG. 288).
- At the top of the dialog, enter the specified device’s System and Device numbers in the text boxes (range = 0-65535).
- Click Get IP Information to populate the IP Address fields with the current Host Name, IP Address, Subnet Mask and Gateway
assignments.
- Click the Specify IP Address option button, and enter the new IP Address, Subnet Mask and Gateway assignments in the text boxes, as necessary.
- Click Set IP Information to set the new IP Address assignment.
- Click Reboot Master to reboot the master and accept the new changes. Allow 20-30 seconds for the master to reboot.
Setting the DNS Address for a NetLinx Master
- Select Diagnostics > Network Addresses to access the Network Addresses dialog (see FIG. 288).
- Enter the specified device’s System and Device values in the text boxes at the top of the dialog (range = 0-65535).
- Click Get DNS Information to populate the DNS Address fields with the current Domain Suffix, DNS IP Address #1, DNS IP Address #2 and DNS IP Address #3 assignments (as applicable).
- Edit the DNS Address assignments and/or add new DNS address information as needed.
- Click Set DNS Information to set the new DNS address assignments.
- Click Reboot Master to reboot the master and accept the new changes. Allow 20-30 seconds for the master to reboot.
Changing the IP Address on a NetLinx Device Using DHCP
- Select Diagnostics > Network Addresses to access the Network Addresses dialog (see FIG. 288).
- Enter the specified device’s System and Device values in the text boxes at the top of the dialog (range = 0-65535).
- Click Get IP Information to populate the IP Address fields with the current Host Name and Gateway assignments.
- Select Use DHCP, and enter a new Host Name in the field, if necessary.
- Click the Set IP Information button to set the new Host Name assignment.
- Click Reboot Master to reboot the master and accept the new changes. Allow 20-30 seconds for the master to reboot.
Changing the IP Address on a NetLinx Master (Specify IP Address)
- Select Diagnostics > Network Addresses to access the Network Addresses dialog (see FIG. 288).
- Enter the specified device’s System and Device values in the text boxes at the top of the dialog (range = 0-65535).
- Click Get IP Information to populate the IP Address fields with the current Host Name, IP Address, Subnet Mask and Gateway
assignments.
- Select Specify IP Address, and enter the new IP Address, Subnet Mask and Gateway assignments in the text boxes, as necessary.
- Click Set IP Information to set the new IP Address assignment. A message will be displayed indicating that the Master has accepted the new settings.
- Click Reboot Master to reboot the Master and accept the new changes. Allow 20-30 seconds for the Master to reboot.